Multi-Conductor Cables
16 Channel, multi-conductor cables are shielded and wired for PCB® equipment specifically. Shielding minimizes noise when located near other power or signal cables. Custom versions are also available on request. Instrumentation-grade BNC / DB-50 connectors are provided to interface with Patch Panels and Signal Conditioners.
Multi-Conductor Cables |
| | | | | | | |
Model | 009A10 | 009V15 | 009M220/005 | 009H50 | 009F10 | 009B00/010 | 009N03 |
Cable Style Multi-Conductor - Ruggedized | Multi-Conductor - General | Multi-Conductor - Ruggedized | Multi-Conductor - Ribbon | Multi-Conductor - Ribbon | Multi-Conductor - Ruggedized | Multi-Conductor - Ribbon | Multi-Conductor - Ribbon |
Description | Multi-conductor shielded cable, ruggedized, 10-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY) | Multi-conductor shielded cable, 15-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY) | Multi-conductor shielded cable, ruggedized, 10-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY) | Multi-conductor, shielded flat ribbon cable, 50-ft, DB50 female to DB50 male (Wired for PCB equipment ONLY) | Multi-conductor, unshielded flat ribbon cable, 10-ft, DB50 female to DB50 male (Wired for PCB equipment ONLY) | Multi-conductor shielded cable, ruggedized, 10-ft, DB50 female to DB50 male (Wired for PCB equipment ONLY) | Multi-conductor, unshielded flat ribbon cable, 10-ft, DB50 female to DB50 male (Wired for PCB equipment ONLY) |
Jacket Material | PVC | FEP | PVC | PVC | PVC | PVC | PVC |
Type of Use | Patch Panel & DAQ | Patch Panel & DAQ | Patch Panel & DAQ | Gender Changer | Gender Changer | Gender Changer | Communication Cable |
Connector 1 | DB50 Female | DB50 Female | DB50 Female | DB50 Female | DB50 Female | DB50 Female | 9-pin Female |
Connector 2 | (16) BNC Plug | (16) BNC Plug | (16) BNC Plug w/ Drain | DB50 Male | DB50 Male | DB50 Male | 9-pin Male & 9-pin Female |
Length | 10 ft (3 m) | 15ft (4.6 m) | 5 ft (1.5 m) | 50 ft (15.3 m) | 10 ft (3 m) | 10 ft (3 m) | 3ft (0.9 m) |
Temperature Range | -31 to 167 °F (-35 to +75 °C) | -85 to 212 °F (-65 to +100 °C) | -31 to 167 °F (-35 to +75 °C) | -31 to 221 °F (-35 to +105 °C) | -40 to 221 °F (-40 to +105 °C) | -31 to 167 °F (-35 to +75 °C) | -40 to 221 °F (-40 to +105 °C) |
Nominal Cable Size | Æ0.63 in (16 mm) | Æ0.075 in (1.9 mm) | Æ0.63 in (16 mm) | 0.12 in (2.9 mm) Thick | 0.04 in (0.9 mm) Thick | Æ0.63 in (16 mm) | 0.04 in (0.9 mm) Thick |
Bend Radius | 6.5 in (16.5 cm) | 0.8 in (20 cm) | 6.5 in (16.5 cm) | – | – | 6.5 in (16.5 cm) | – |
Cable Bulk Weight | 225 lbs per 1000 ft | 6.25 lb per 1000 ft | 225 lbs per 1000 ft | – | – | 225 lbs per 1000 ft | – |
Center Conductor Style | Stranded, shielded twisted pair | Stranded, coax | Stranded, shielded twisted pair | Stranded, shielded ribbon | Stranded, unshielded ribbon | Stranded, shielded twisted pair | Stranded, unshielded ribbon |
Center Conductor Material | Tinned Copper | Silver Copper Covered Steel | Tinned Copper | Tinned Copper | Tinned Copper | Tinned Copper | Tinned Copper |
Conductor Size | 24 AWG (7/32) | 30 AWG (7/38) | 24 AWG (7/32) | 28 AWG (7/36) | 28 AWG (7/36) | 24 AWG (7/32) | 28 AWG (7/36) |
Shield Type Coverage | Inner/Outer: Foil w/ Drain | Braid | Inner/Outer: Foil w/ Drain | Foil w/ Dual Drain | – | Inner/Outer: Foil w/ Drain | – |
Full specifications | 009A10 | 009V15 | 009M220/005 | 009H50 | 009F10 | 009B00/010 | 009N03 |