Products

platinum stock products; low-cost, general purpose, industrial ceramic shear icp® accel, 100 mv/g, 0.5 to 10k hz, top exit, 10-ft integral cable, m6 mounting stud, single point iso 17025 accredited calibration
platinum

Platinum Low-cost Industrial ICP® Accelerometer

Model M608A11

Retrieving Price...

(Pricing valid only in the U.S.)

Units in Stock Lead Times
More on the way Lead Time for 1-10 is 14 Dys.
Lead Time for 11-20 is 3 Wks.
  • CE
  • IP

Platinum Stock Products; Low-cost, general purpose, industrial ceramic shear ICP® accel, 100 mV/g, 0.5 to 10k Hz, top exit, 10-ft integral cable, M6 mounting stud, single point ISO 17025 accredited calibration

Low-cost industrial accelerometer with integral 10 ft. cable to blunt termination, 100 mV/g, general purpose, submersible, ceramic shear ICP®, 0.5 to 10k Hz, top exit.
  • Sensitivity: (±15%)100 mV/g (10.2 mV/(m/s²))
  • Frequency Range: (±3dB)30 to 600000 cpm (0.5 to 10000 Hz)
  • Sensing Element: Ceramic
  • Measurement Range: ±50 g (±490 m/s²)
  • Weight: 3.5 oz (99.3 gm)

Additional configurations:

Specification Notes


[1] Conversion Factor 1g = 9.81 m/s².
[2] Zero-based, least-squares, straight line method.
[3] Typical.
[4] Twisted shielded pair.
[5] 1/4-28 has no equivalent in S.I. units.
[6] See PCB Declaration of Conformance PS023 or PS060 for details.

English: SI:
Performance
Sensitivity (±15 %) 100 mV/g 10.2 mV/(m/s²) [1]
Measurement Range ±50 g ±490 m/s²
Frequency Range (±3 dB) 30 to 600000 cpm 0.5 to 10000 Hz
Resonant Frequency 1320 kcpm 22 kHz [3]
Broadband Resolution (1) 350 µg 3434 µm/sec2 [3]
Non-Linearity ±1 % ±1 % [2]
Transverse Sensitivity ≤7 % ≤7 %
Environmental
Overload Limit (Shock) 5000 g pk 49050 m/s² pk
Temperature Range -65 to +250 °F -54 to +121 °C
Temperature Response See Graph %/°F See Graph %/°F [3]
Enclosure Rating IP68 IP68
Electrical
Settling Time (within 1% of bias) ≤2.0 sec ≤2.0 sec
Discharge Time Constant ≥0.3 sec ≥0.3 sec
Excitation Voltage 18 to 28 VDC 18 to 28 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance <150 Ohm <150 Ohm
Output Bias Voltage 8 to 12 VDC 8 to 12 VDC
Spectral Noise (10 Hz) 8 µg/√Hz 78.5 (µm/sec2)/√Hz [3]
Spectral Noise (100 Hz) 5 µg/√Hz 49.1 (µm/sec2)/√Hz [3]
Spectral Noise (1 kHz) 4 µg/√Hz 39.2 (µm/sec2)/√Hz [3]
Electrical Isolation (Case) >100000000 Ohm >100000000 Ohm
Physical
Size - Hex 9/16 in 14 mm
Size - Height 2.5 in 64 mm
Weight (with cable) 3.5 oz 99.3 gm
Mounting Stud Stud
Mounting Thread 1/4-28 Female 1/4-28 Female [5]
Mounting Torque 2 to 5 ft-lb 2.7 to 6.8 Nm
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Housing Material Stainless Steel Stainless Steel
Sealing Molded Molded
Electrical Connector Molded Integral Cable Molded Integral Cable
Electrical Connection Position Top Top
Cable Length 10 ft 3 m
Cable Type Polyurethane Polyurethane [4]

* All specifications are at room temperature unless otherwise specified.

TempChart

Accessories


Supplied
081A40 Mounting stud, 1/4-28 x 0.438" long stainless steel screw with hex socket and brass tip 1
ICS-2 Calibration of industrial accel., single-point, 100 Hz reference sensitivity 1

Optional Versions


(EX) Hazardous Area Approval- contact factory for specific approvals

English SI
Hazardous Area Approval EEx nL IIC 1T4, -40 = Ta = 121°C, II 3 G
Hazardous Area Approval EEx nL IIC T4, -40 ° C ≤ Ta ≤ 121 ° C, II 1 G
Hazardous Area Approval Cl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I
Hazardous Area Approval Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4
Hazardous Area Approval Ex ia IIC T4, AExia IIC, T4

(LB) Low Bias Voltage

English SI
Output Bias Voltage 4.8 to 6.5
Excitation Voltage 12 to 28
Measurement Range ±10 ±98
(M) Metric Mount
Accessories:
Supplied M081A61 Mounting Stud 1

(TO) Temperature Output

English SI
Temperature Scale Factor 5.56 mV/°F + 32 +10 mV/°C
Electrical Connections Acceleration Output
Electrical Connections Ground
Temperature Output Range +36 to +250 °F +2 to +121 °C
Electrical Connector Molded Integral Cable
Electrical Connections Temperature Output

Build Out Your Measurement Chain