Products

tourmaline icp underwater blast sensor

ICP® Pressure Sensor

Model W138A02/

  • CE
  • IP

Tourmaline ICP underwater blast sensor

Photo shown with special W option attached underwater cable. Standard model supplied with 10-32 jack.
  • Measurement Range: 1000 psi (6895 kPa)
  • Sensitivity: (±15%)5 mV/psi (0.73 mV/kPa)
  • Low Frequency Response: (-5%)1.7 Hz
  • Resonant Frequency: >=1000 kHz
  • Electrical Connector: 10-32 Coaxial Jack
  • Weight: 0.61 oz (17.0 gm)

Specification Notes


[1] Zero-based, least-squares, straight line method.
[2] Typical.
[3] For +10 volt output, minimum 24 VDC supply voltage required. Negative 10 volt output may be limited by output bias.
[4] See PCB Declaration of Conformance PS023 for details.

English: SI:
Performance
Measurement Range (for ±5V output) 1000 psi 6895 kPa
Useful Overrange (for ± 10V output) 2000 psi 13790 kPa [3]
Sensitivity (±15 %) 5 mV/psi 0.73 mV/kPa
Maximum Pressure 50000 psi 344750 kPa
Resolution 0.02 psi 0.14 kPa [2]
Resonant Frequency ≥1000 kHz ≥1000 kHz
Rise Time (Reflected) ≤1.5 µ sec ≤1.5 µ sec
Low Frequency Response (-5 %) 1.7 Hz 1.7 Hz
Non-Linearity ≤2.0 % FS ≤2.0 % FS [1]
Environmental
Temperature Range (Operating) -10 to +100 °F -23 to +37.8 °C
Maximum Shock 20000 g pk 196140 m/s² pk
Electrical
Output Polarity (Positive Pressure) Positive Positive
Discharge Time Constant (at room temp) ≥0.3 sec ≥0.3 sec
Excitation Voltage 20 to 30 VDC 20 to 30 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance ≤100 Ohm ≤100 Ohm
Output Bias Voltage 8 to 14 VDC 8 to 14 VDC
Physical
Sensing Element Tourmaline Tourmaline
Housing Material Stainless Steel Stainless Steel
Electrical Connector 10-32 Coaxial Jack 10-32 Coaxial Jack
Weight 0.61 oz 17.0 gm

* All specifications are at room temperature unless otherwise specified.

Accessories


Supplied
PCS-6 Calibration of Series 134, 137 & 138 0

Optional Versions