Products

icp® triaxial shock accelerometer, 1.0 mv/g, 5k g range, mechanically isolated and electrically filtered, 5-ft integral cable

Triaxial ICP® Accelerometer

Model 350B44

Retrieving Price...

(Pricing valid only in the U.S.)

Units in Stock Lead Times
More on the way Call for Lead Time
  • CE
  • IP

ICP® Triaxial shock accelerometer, 1.0 mV/g, 5k g range, mechanically isolated and electrically filtered, 5-ft integral cable

  • Sensitivity: (±30%)1.0 mV/g (.1 mV/(m/s²))
  • Measurement Range: ±5000 g pk (±49000 m/s² pk)
  • Frequency Range: (±1dB)0.4 to 10000 Hz
  • Electrical Connector: Integral Cable (Integral Cable)

Specification Notes


[1] Typical.
[2] Typical corner frequency for coupled electrical and mechanical filters.
[3] Electrical filter is a second order filter.
[4] Amplitude at resonance is +9 dB.
[1] Typical.
[5] Test performed on a shaker at 100Hz
[1] Typical.
[6] See PCB Declaration of Conformance PS023 for details.

English: SI:
Performance
Sensitivity (±30 %) 1.0 mV/g .1 mV/(m/s²)
Measurement Range ±5000 g pk ±49000 m/s² pk
Frequency Range (±1 dB) 0.4 to 10000 Hz 0.4 to 10000 Hz
Frequency Range (-3 dB) 0.2 to 25000 Hz 0.2 to 25000 Hz [2]
Resonant Frequency >50 kHz >50 kHz
Electrical Filter Corner Frequency (3) 17 kHz 17 kHz [1] [3]
Mechanical Filter Resonant Frequency 35 kHz 35 kHz [1] [4]
Broadband Resolution (1) 0.04 g rms 0.39 m/s² rms [1]
Non-Linearity (per 1000 g (9810 m/s2)) 2.0 % 2.0 %
Transverse Sensitivity ≤7 % ≤7 %
Environmental
Overload Limit (Shock) ±50000 g pk ±490000 m/s² pk
Temperature Range (Operating) -10 to +150 °F -23 to +66 °C
Temperature Range (Storage) -40 to +200 °F -40 to +93 °C
Temperature Response See Graph %/°F See Graph %/°F [1] [5]
Base Strain Sensitivity 0.002 g/µε 0.02 (m/s²)/µε [1]
Electrical
Excitation Voltage 20 to 30 VDC 20 to 30 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance ≤200 Ohm ≤200 Ohm
Output Bias Voltage 8 to 14 VDC 8 to 14 VDC
Discharge Time Constant 1.0 to 2.0 sec 1.0 to 2.0 sec [1]
Settling Time (within 10% of bias) <10 sec <10 sec
Electrical Isolation (Case) >100000000 Ohm >100000000 Ohm
Physical
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Housing Material Titanium Titanium
Sealing Hermetic Hermetic
Size - Height 1.02 in 26.0 mm
Size - Length 1.02 in 26.0 mm
Size - Width 1.02 in 26.0 mm
Weight (without cable) 0.95 oz 27 g [1]
Electrical Connector Integral Cable Integral Cable
Electrical Connection Position Side Side
Cable Termination 1/4-28 4-Pin Jack 1/4-28 4-Pin Jack
Cable Length 5.0 ft 1.52 m
Cable Type 034 4-cond Shielded 034 4-cond Shielded
Mounting Through Hole Through Hole

* All specifications are at room temperature unless otherwise specified.

TempChart

Accessories


Supplied
034G05 4-conductor, low noise, shielded FEP cable, 5-ft, 4-socket plug to (3) BNC plugs (labeled X Y Z) 1
100-16040-40 1
100-6774-10 1
100-8994-40 1
ACS-14T 1
ACS-22T Triaxial amplitude response calibration for shock accelerometer, 100 Hz to upper 1 dB frequency (max 15 kHz) 1

Build Out Your Measurement Chain