dual bridge, fatigue rated, low profile load cell, 5k lbf fs, 5/8-18 (f) thd, pt02e-10-6p connectors

FATIGUE RATED LOW PROFILE LOAD CELL, DUAL BRIDGE

Model 1403-05ADB

Retrieving Price...

(Pricing valid only in the U.S.)

Units in Stock Lead Times
More on the way Call for Lead Time
  • IP

Dual bridge, fatigue rated, low profile load cell, 5k lbf FS, 5/8-18 (F) thd, PT02E-10-6P connectors

Specifically designed for airframe structural, lifetime and fatigue testing applications on wings, fuselage, landing gear, iron bird and other airframe components.•Series 1400 includes a dual output feature that offers sensor redundancy and the ability to provide control feedback from one output while the other is used for data acquisition•A2LA accredited calibration to ISO 17025 in both tension and compression directions•Fatigue rated load cells are guaranteed for 100 million fully-reversed cycles•Thermally compensated•Moment compensated•A single shunt calibration resistor is provided with each load cell for ease of calibration at the test site


Cable <20ft: 8311-04-xxA8311-17-xxA and 8311-01-xxA
  • Measurement Range: 5000 lb (22 kN)
  • Size - Diameter: 4.12 in (104.60 mm)
  • Size - Height: 2.50 in (63.50 mm)
  • Electrical Connector: PT02E-10-6P (2)

Specification Notes


[1] Nominal.
[2] FS - Full Scale.
[3] RO - Rated Output.
[4] Calibrated in tension and compression.
[5] Singularly applied, i.e. no other extraneous loads.
[6] Over compensated operating temperature range.
[1] Nominal.
[7] Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS.
[8] See Outline Drawing 49605 for Complete Dimensions

English: SI:
Performance
Measurement Range (100 x 10^6 cycles) 5000 lb 22 kN [2] [4]
Sensitivity (±10 %) 2.0 mV/V 2.0 mV/V [1] [3]
Non-Linearity ≤0.04 % FS ≤0.04 % FS
Hysteresis ≤0.04 % FS ≤0.04 % FS
Non-Repeatability ≤0.02 %RO ≤0.02 %RO
Creep (in 20 minutes) 0.025 % 0.025 %
Static Error Band ≤0.04 % FS ≤0.04 % FS [2]
Eccentric Load Sensitivity 0.1 %/in 0.1 %/25.4mm
Resonant Frequency 10 kHz 10 kHz
Side Load Sensitivity 0.1 %/in 0.1 %/25.4mm
Environmental
Overload Limit 15 klb 67 kN
Load Limit (Side Force, FX or FY) 5000 lb 22 kN [5]
Load Limit (Bending Moment, MX or MY) 5000 in-lb 565 Nm [5]
Load Limit (Axial Torque, MZ) 5000 in-lb 565 Nm [5]
Temperature Range (Operating) -65 to +200 °F -54 to +93 °C
Temperature Range (Compensated) +15 to +115 °F -9 to +46 °C
Temperature Effect on Output (Maximum) ±0.0008 %Reading/°F ±0.0018 %Reading/°C [6]
Temperature Effect on Zero Balance (Maximum) ±0.0008 %FS/°F ±0.0018 %FS/°C [6]
Electrical
Bridge Resistance 350 Ohm 350 Ohm [1]
Excitation Voltage (Recommended) 10 VDC 10 VDC [7]
Insulation Resistance >5k GOhm >5k GOhm
Zero Balance ≤1 %RO ≤1 %RO
Output Polarity +Tension +Tension
Physical
Size - Height 2.50 in 63.50 mm [8]
Size - Diameter 4.12 in 104.60 mm [8]
Weight 6.4 lb 2.9 kg
Mounting Thread 5/8 - 18 UNF-3B No Metric Equivalent
Sensing Element Strain Gage Strain Gage
Mounting Torque 200 in-lb 23 Nm
Deflection at Full Scale Capacity 0.001 in 0.03 mm
Electrical Connector PT02E-10-6P (2) PT02E-10-6P (2)

* All specifications are at room temperature unless otherwise specified.

Accessories


Optional
084A55 Load cell thread pre-tensioner 5/8-18 1
181-012A Mating conn., 6-socket (F) w/strain relief for sensors with PT conn. PT06A-10-6S (SR) 1
8311-01-10A 4-conductor, PT06A-10-6S to pigtails cable, 10-ft, for Reaction Torque and Load Cells with PT connector (& 8162 Series), <20 ft 1
Supplied