Model: 426E01

Model: 426E01

ICP® microphone preamplifier 1/2" to be used with prepolarized condenser microphone.
  • Nominal Microphone Diameter: 1/2 in
  • Temperature Range: (Operating) -40 to +176 °F(-40 to +80 °C)
  • Output Voltage: (Maximum) ±7 Vpk
  • Size - Length: 3.18 in(80.7 mm)

Model: HT426E01

Model: HT426E01

High temperature 1/2-inch preamplifier
  • Nominal Microphone Diameter: 1/2 in
  • Temperature Range: (Operating) -40 to +257 °F(-40 to +125 °C)
  • Output Voltage: (Maximum) ±7 Vpk
  • Size - Length: 3.5 in(89 mm)

Model: 378A21

Model: 378A21

377A21 Microphone and 426E01 preamplifier with TEDS
  • Nominal Microphone Diameter: 1/2 in
  • Frequency Response Characteristic: Random Incidence
  • Frequency Range: (±2dB) 4 to 25000 Hz
  • Dynamic Range: (3% Distortion Limit) 150 dB re 20 µPa

Model: 378A07

Model: 378A07

377A07 microphone with 426E01 preamplifier and 079A43 adaptor TEDS programmed
  • Nominal Microphone Diameter: 1/2 in
  • Frequency Response Characteristic: (at 0° incidence) Free-Field
  • Frequency Range: (±2dB) 0.13 to 20000 Hz
  • Dynamic Range: (3% Distortion Limit) 136 dB re 20 µPa

Model: 378A06

Model: 378A06

1/2" prepolarized free field condenser microphone, with 1/2" ICP® 426E01 preamplifier
  • Nominal Microphone Diameter: 1/2 in
  • Frequency Response Characteristic: Free-Field
  • Frequency Range: (±3dB) 3.15 to 40000 Hz
  • Dynamic Range: (3% Distortion Limit) 150 dB re 20 µPa

Model: 378B02

Model: 378B02

1/2" prepolarized free-field condenser microphone, 50 mV/Pa (+/-1.5 dB), 3.75 Hz - 20 kHz (+/-2 dB) with 1/2" ICP® preamplifier (426E01) and TEDS
  • Nominal Microphone Diameter: 1/2 in
  • Frequency Response Characteristic: (at 0° incidence) Free-Field
  • Frequency Range: (±2dB) 3.75 to 20000 Hz(3.75 to 20000 Hz)
  • Inherent Noise: 15.5 dB(A) re 20 µPa
  • Dynamic Range: (3% Distortion Limit) 137 dB re 20 µPa

Model: 378C13

Model: 378C13

TEDS 377C13 pressure microphone and 426E01 preamplifier, 12.6 mV/Pa (+/-2 dB), 3.2 Hz to 20 kHz (+/-2 dB), 4Hz to 12.5 kHz (+/-1 dB)
  • Nominal Microphone Diameter: 1/2 in
  • Frequency Response Characteristic: Pressure
  • Frequency Range: (±2dB) 3.15 to 20000 Hz
  • Dynamic Range: (3% Distortion Limit) 150 dB re 20 µPa

Model: 378B11

Model: 378B11

1/2-inch pressure, prepolarized microphone and preamplifier, TEDS programmed
  • Nominal Microphone Diameter: 1/2 in
  • Frequency Response Characteristic: Pressure
  • Frequency Range: (±2dB) 3.75 to 10000 Hz(3.75 to 10000 Hz)
  • Dynamic Range: (3% Distortion Limit) 137 dB re 20 µPa


	Low Frequency | PCB Piezotronics

Low Frequency | PCB Piezotronics

For applications measuring infrasound (below the human hearing threshold) microphone model 378A07 provides the capability to measure to 0.1 Hz (-3dB).


	Specialty Microphones | PCB Piezotronics

Specialty Microphones | PCB Piezotronics

When acoustic measurements need to be made in demanding environments and applications, trust PCB specialty microphones.

tm-ac-377a06_lowres.pdf

tm-ac-377a06_lowres.pdf

en-US 1/2” High Frequency and High Amplitude en-US Prepolarized Microphone en-US Model 37

tm-ac-catalog_lowres.pdf

tm-ac-catalog_lowres.pdf

en-US ACO U S T I C en-US ME A S U R E ME N T en-US S E N S ORS &

tm_ac_catalog_lowres.pdf

tm_ac_catalog_lowres.pdf

en-US ACO U S T I C en-US ME A S U R E ME N T en-US S E N S ORS &

tm-ac-378c13_lowres.pdf

tm-ac-378c13_lowres.pdf

en-US p c b . c o m | 1 8 0 0 8 2 8 8 8 4 0 en-US T Y P I CA L A PPL I CA

tm-ac-378a21_lowres.pdf

tm-ac-378a21_lowres.pdf

en-US p c b . c o m | 1 8 0 0 8 2 8 8 8 4 0 en-US U S E O F MO D E L 3 7 8

tm-ac-378a21_lowres.pdf

tm-ac-378a21_lowres.pdf

en-US p c b . c o m | 1 8 0 0 8 2 8 8 8 4 0 en-US U S E O F MO D E L 3 7 8

1/2" Random Incidence Prepolarized Mic and Preamp

1/2" Random Incidence Prepolarized Mic and Preamp

Model 377A21 is a prepolarized microphone for diffuse field applications to measure beyond the human hearing range and where a wide range of frequencies or higher amplitudes are required

tm-ac-microcatalog_lowres.pdf

tm-ac-microcatalog_lowres.pdf

en-US M I C R OP HON E S , en-US S Y S T EM S , & en-US A C C ESS O

tm-ac-series426_lowres.pdf

tm-ac-series426_lowres.pdf

en-US p c b . c o m | 1 8 0 0 8 2 8 8 8 4 0 en-US SERIES en-US 426 en-US P R

pcb-ac-preamps_lowres.pdf

pcb-ac-preamps_lowres.pdf

en-US M I C R OP HON E S , en-US S Y S T EM S , & en-US A C C ESS O

tm-ac-series426_lowres.pdf

tm-ac-series426_lowres.pdf

en-US p c b . c o m | 1 8 0 0 8 2 8 8 8 4 0 en-US SERIES en-US 426 en-US P R

Microphones

Microphones

PERFORMANCE, UNBEATABLE PRICE, 24/7 SUPPORT, BEST WARRANTY, FAST SHIPMENT

In-line A-weighting filter

In-line A-weighting filter

For Acoustic Measurements Utilizing “Prepolarized” Microphones and ICP® Microphone Preamplifiers

Preamplifiers for Measurement Microphones

Preamplifiers for Measurement Microphones

A portfolio of 1/2” and 1/4” preamplifiers for all your test applications

Preamplifiers for measurement microphones

Preamplifiers for measurement microphones

n-US 426E01 en-US HT426E01 en-US Polarization Design en-US Prepolarized en-US Prepolarized en-US Prepolarized en-US Ext. Polarized en-US Prepolarized en-US Prepolarized en-US Attenuation/Gain en-US -0.1 dB [1][2] en-US -0.16 dB [1][2] en-US -0.2 dB [1][2] en-US -0.2 dB

ad-flighttest_lowres.pdf

ad-flighttest_lowres.pdf

en-US A ER O S P A CE en-US en-US F LI G H T T E S T en-US p c b . c o

Aerospace Flight Test

Aerospace Flight Test

Miniature, Triaxial, and High-Temperature Accelerometers, DC Response Accelerometers, Acoustic Microphones, Pressure Sensors, Signal Conditioning, and Accessories

testandmeasurementcatalog.pdf

testandmeasurementcatalog.pdf

en-US T E S T & ME A S U R E ME N T en-US S E N S ORS A N D en-US

Test & Measurement Sensors & Instrumentation

Test & Measurement Sensors & Instrumentation

Acceleration & Vibration, Acoustics, Pressure, Force, Load, Strain, Shock, & Torque

ad-groundtest_lowres.pdf

ad-groundtest_lowres.pdf

en-US A ER O S P A CE en-US GR O U ND T E S T en-US p c b . c o m / g r

Aerospace Ground Test

Aerospace Ground Test

Accelerometers, Dynamic Force Sensors, Modally Tuned®, ICP® Impact Hammers, Modal Analysis Sensors, Electrodynamic Modal Shakers, Strain Gage Load Cells, Pressure Transducers and Accessories