For advanced search by sensor specifications or product family, please visit our Shop Sensors tool.


Do You Have Any Questions?

Toll-free (in the US): 800-828-8840
Fax: 1-716-684-0987
Contact PCB®

We found 27 matches....
Model: 379A02

Model: 379A02

Grid Array microphone stand & holders

    Model: 378A04

    Model: 378A04

    MICROPHONE AND PREAMPLIFIER, LOW NOISE, 1/2" FREE-FIELD PREPOLARIZED
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: (at 0° incidence) Free-Field
    • Frequency Range: (±4dB) 5 to 20000 Hz
    • Inherent Noise: 5.5 dB(A) re 20 µPa
    • Dynamic Range: (3% Distortion Limit) >80 dB re 20 µPa

    Model: 378A06

    Model: 378A06

    1/2" prepolarized free field condenser microphone, with 1/2" ICP® 426E01 preamplifier
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: Free-Field
    • Frequency Range: (±3dB) 3.15 to 40000 Hz
    • Dynamic Range: (3% Distortion Limit) 150 dB re 20 µPa

    Model: 378A07

    Model: 378A07

    377A07 microphone with 426E01 preamplifier and 079A43 adaptor TEDS programmed
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: (at 0° incidence) Free-Field
    • Frequency Range: (±2dB) 0.13 to 20000 Hz
    • Dynamic Range: (3% Distortion Limit) 136 dB re 20 µPa

    Model: 378A08

    Model: 378A08

    MICROPHONE AND PREAMPLIFIER, LOW NOISE, 1/4" FREE-FIELD PREPOLARIZED
    • Nominal Microphone Diameter: 1/4 in
    • Frequency Response Characteristic: (at 0° incidence) Free-Field
    • Frequency Range: (±2dB) 12 to 20000 Hz
    • Inherent Noise: 22 dB(A) re 20 µPa
    • Dynamic Range: (3% Distortion Limit) 123 dB re 20 µPa

    Model: 378A14

    Model: 378A14

    1/4" pressure prepolarized 377A14 microphone and 426A05 preamplifier, TEDS programmed
    • Nominal Microphone Diameter: 1/4 in
    • Frequency Response Characteristic: Pressure
    • Frequency Range: (±2dB) 4.0 to 70000 Hz(4.0 to 70000 Hz)
    • Dynamic Range: (3% Distortion Limit) 173 dB re 20 µPa

    Model: 378A21

    Model: 378A21

    377A21 Microphone and 426E01 preamplifier with TEDS
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: Random Incidence
    • Frequency Range: (±2dB) 4 to 25000 Hz
    • Dynamic Range: (3% Distortion Limit) 150 dB re 20 µPa

    Model: 378B02

    Model: 378B02

    1/2" prepolarized free-field condenser microphone, 50 mV/Pa (+/-1.5 dB), 3.75 Hz - 20 kHz (+/-2 dB) with 1/2" ICP® preamplifier (426E01) and TEDS
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: (at 0° incidence) Free-Field
    • Frequency Range: (±2dB) 3.75 to 20000 Hz(3.75 to 20000 Hz)
    • Inherent Noise: 15.5 dB(A) re 20 µPa
    • Dynamic Range: (3% Distortion Limit) 137 dB re 20 µPa

    Model: 378B11

    Model: 378B11

    1/2-inch pressure, prepolarized microphone and preamplifier, TEDS programmed
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: Pressure
    • Frequency Range: (±2dB) 3.75 to 10000 Hz(3.75 to 10000 Hz)
    • Dynamic Range: (3% Distortion Limit) 137 dB re 20 µPa

    Model: 378C01

    Model: 378C01

    1/4" free-field, prepolarized 377C01 microphone and 426B03 preamplifier. TEDS programmed
    • Nominal Microphone Diameter: 1/4 in
    • Frequency Response Characteristic: (at 0° incidence) Free-Field
    • Frequency Range: (+2 / -3dB) 4 to 100000 Hz
    • Dynamic Range: (3% Distortion Limit) 165 dB re 20 µPa

    Model: 378C10

    Model: 378C10

    1/4" pressure, prepolarized 377C10 microphone and 426B03 preamplifier. TEDS programmed
    • Nominal Microphone Diameter: 1/4 in
    • Frequency Response Characteristic: Pressure
    • Frequency Range: (±2dB) 5 to 70000 Hz(5 to 70000 Hz)
    • Dynamic Range: (3% Distortion Limit) 173 dB re 20 µPa

    Model: 378C13

    Model: 378C13

    TEDS 377C13 pressure microphone and 426E01 preamplifier, 12.6 mV/Pa (+/-2 dB), 3.2 Hz to 20 kHz (+/-2 dB), 4Hz to 12.5 kHz (+/-1 dB)
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: Pressure
    • Frequency Range: (±2dB) 3.15 to 20000 Hz
    • Dynamic Range: (3% Distortion Limit) 150 dB re 20 µPa

    Model: 378C20

    Model: 378C20

    1/2" prepolarized random-incidence condenser microphone, 50 mV/Pa (+/-1.5 dB), with 1/2" ICP® preamplifier
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: Random Incidence
    • Frequency Range: (±2dB) 3.75 to 16000 Hz
    • Dynamic Range: (3% Distortion Limit) 137 dB re 20 µPa

    Model: 378A12

    Model: 378A12

    1/4-inch pressure prepolarized 377A12 microphone, with 1/4-inch preamplifier 426B03 and TEDS programmed
    • Nominal Microphone Diameter: 1/4 in
    • Frequency Response Characteristic: Pressure
    • Frequency Range: (±2dB) 5 to 20000 Hz(5 to 20000 Hz)
    • Dynamic Range: (3% Distortion Limit) 182 dB re 20 µPa

    Model: EX378B02

    Model: EX378B02

    Intrinsically safe 378B02 microphone and preamplifier, ATEX, IECEx, ETL, ANZEx, approved
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: (at 0° incidence) Free-Field
    • Frequency Range: (±2dB) 3.75 to 20000 Hz(3.75 to 20000 Hz)
    • Inherent Noise: 15.5 dB(A) re 20 µPa
    • Dynamic Range: (3% Distortion Limit) 137 dB re 20 µPa

    Model: HT378A06

    Model: HT378A06

    1/2" prepolarized free field condenser microphone, with 1/2" ICP® HT426E01 preamplifier
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: Free-Field
    • Frequency Range: (±3dB) 3.15 to 40000 Hz
    • Dynamic Range: (3% Distortion Limit) 153 dB re 20 µPa

    Model: HT378A21

    Model: HT378A21

    377A21 Microphone and HT426E01 Preamplifier with TEDS
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: Random Incidence
    • Frequency Range: (±2dB) 4 to 25000 Hz
    • Dynamic Range: (3% Distortion Limit) 153 dB re 20 µPa

    Model: HT378B02

    Model: HT378B02

    377B02 microphone and HT426E01 preamplifier, TEDS programmed
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: (at 0° incidence) Free-Field
    • Frequency Range: (±2dB) 3.5 to 20000 Hz(3.5 to 20000 Hz)
    • Dynamic Range: (3% Distortion Limit) 138.5 dB re 20 µPa
    • Dynamic Range: (3% Distortion Limit) 137 dB re 20 µPa

    Model: HT378C20

    Model: HT378C20

    377C20 microphone and HT426E01 preamplifier, TEDS programmed
    • Nominal Microphone Diameter: 1/2 in
    • Frequency Response Characteristic: Random Incidence
    • Frequency Range: (±2dB) 3.5 to 16000 Hz
    • Dynamic Range: (3% Distortion Limit) 138.5 dB re 20 µPa

    
	Magnets | PCB Piezotronics

    Magnets | PCB Piezotronics

    Magnets that attach to the base of the accelerometer for route-based data collection and roving measurements

    termsandconditionsofsale.pdf

    termsandconditionsofsale.pdf

    PC B PIEZOT RONIC S , INC . TERMS AN D COND ITIONS OF SALE Each q u ote is

    wpl_97_small_mic_nvh.pdf

    wpl_97_small_mic_nvh.pdf

    en-US W r i t t en B y en en-US J e f f D os c h , P C B Pi e z o tr o n

    Small Microphone Has Big Impact on NVH Testing

    Small Microphone Has Big Impact on NVH Testing

    s 378 B 02. W it h it s lo w po w e r , 2 - w ir e I C P ® o pe r a t io n, e x c e ll e nt e nv i r o nm e nt a l s t a bilit y , lo w n o i s e f l o o r , a n d h i gh s en s i t i v i t

    3p03218condensedreport.pdf

    3p03218condensedreport.pdf

    R EP O RT is s u e d b y a S w e d is h N a tio n a l L a b o ra

    Side-by-Side Microphone Test Results

    Side-by-Side Microphone Test Results

    3rd Party Competitive Test Results

    testandmeasurementcatalog.pdf

    testandmeasurementcatalog.pdf

    en-US T E S T & ME A S U R E ME N T en-US S E N S ORS A N D en-US

    Test & Measurement Sensors & Instrumentation

    Test & Measurement Sensors & Instrumentation

    Acceleration & Vibration, Acoustics, Pressure, Force, Load, Strain, Shock, & Torque