platinum stock product handheld shaker, 1g at 159.2 hz (for up to 210 grams total weight of sensor, cable and mtg. accessories).
platinum

Hand-Held Shaker

Model 394C06

Retrieving Price...

(Pricing valid only in the U.S.)

Units in Stock Lead Times
More on the way Lead Time for 1-5 is 3 Wks.
Lead Time for 6-10 is 5 Wks.
  • CE
  • IP

Platinum Stock Product Handheld shaker, 1g at 159.2 Hz (for up to 210 grams total weight of sensor, cable and mtg. accessories).

  • Acceleration Output: (±3%)1.00 g rms (9.81 m/s² rms)
  • Velocity Output: 0.39 in/sec rms (9.81 mm/s rms)
  • Operating Frequency: (±1%)159.2 Hz
  • Maximum Load: 7.4 oz (210 gm)
  • Weight: 31 oz (900 gm)

Specification Notes


[1] Maximum load includes sensor, connector and cabling.
[2] Approximate values, based on automatic switch off time and dependent on type of batteries.
[3] Unit supplied set to auto shut off; see manual for continuous use selection.
[4] Calculated values for reference only.
[5] Unit supplied set to rms; see manual for peak selection.
[6] Typical.
[2] Approximate values, based on automatic switch off time and dependent on type of batteries.
[7] Alkaline type recommended for longest service life.
[8] Maximum.
[9] This specification for external DC power supply (optional).
[6] Typical.
[10] Test sensor should be hand tightened (without tools).
[11] Transducer to shaker table.
[12] See PCB Declaration of Conformance PS022 for details.

English: SI:
Performance
Operating Frequency (±1 %) 159.2 Hz 159.2 Hz
Acceleration Output (±3 %) 1.00 g rms 9.81 m/s² rms [5]
Velocity Output 0.39 in/sec rms 9.81 mm/s rms [4]
Displacement Output 0.39 mil rms 9.81 µm rms [4]
Transverse Output ≤3 % ≤3 %
Distortion (0 to 99 grams load) ≤2 % ≤2 %
Distortion (100 to 149 grams load) ≤5 % ≤5 %
Distortion (150 to 210 grams load) ≤9 % ≤9 %
Maximum Load 7.4 oz 210 gm [1]
Automatic Switch Off Time 1.0 to 2.5 minutes 1.0 to 2.5 minutes [3]
Calibration Cycles (2 gram load) 320 cycles 320 cycles [2]
Calibration Cycles (25 gram load) 600 cycles 600 cycles [2]
Calibration Cycles (50 gram load) 1600 cycles 1600 cycles [2]
Calibration Cycles (100 gram load) 400 cycles 400 cycles [2]
Calibration Cycles (150 gram load) 160 cycles 160 cycles [2]
Calibration Cycles (210 gram load) 80 cycles 80 cycles [2]
Environmental
Temperature Range (Operating) +15 to +130 °F -10 to +55 °C
Electrical
Ramp-Up time ≤3 sec ≤3 sec [6]
Internal Battery (Quantity) 4 4
Internal Battery (Type) AA AA [7]
DC Power (±5 %) 12 VDC 12 VDC [9]
DC Power 1.67 Amps 1.67 Amps [8] [9]
Battery Life (2 gram load) 8 hours 8 hours [2]
Battery Life (25 gram load) 15 hours 15 hours [2]
Battery Life (50 gram load) 40 hours 40 hours [2]
Battery Life (100 gram load) 10 hours 10 hours [2]
Battery Life (150 gram load) 4 hours 4 hours [2]
Battery Life (210 gram load) 2 hours 2 hours [2]
Physical
Size - Diameter 2.2 in 56 mm
Size - Height 7.8 in 200 mm
Weight (with batteries) 31 oz 900 gm [6]
Mounting Thread 10-32 Female 10-32 Female [10] [11]
Mounting Torque (Maximum) 10 in-lb 112 N-cm [11]

* All specifications are at room temperature unless otherwise specified.

Accessories


Supplied
073A15 Battery clip for the 394C06 hand held shaker 1
Optional
073A16 DC switching power supply (for Model 394C06 699B02) 1
Supplied
080A109 Petro Wax, one square, 1" x 1" x 0.25" 1
Optional
080A150 Mounting pad, 1/4-28 thd (for Model 394C06) 1
Supplied
080A178 Adhesive mtg base, 0.5" hex x 0.12" thk, 10-32 integral stud, aluminum w/ insulating hardcoat finish 1
080A84 Calibration adapter fixture stainless steel, 0.75" dia., 5-40 female to 10-32 male 1
080A85 Calibration adaptor fixture, M3 x 0.50 tapped hole to integral 10-32 thd stud 1
Optional
080B44 Calibrator adaptor with jumper cable, 3-pin to 2-pin Microtech with Model 070A36 (for Model 333B) 1
Supplied
081A08 Mounting stud, 10-32 to 1/4-28 x 0.30" long, BeCu 1
M081B05 Mounting stud, 10-32 to M6x0.75-6g, 0.275" long, BeCu 1
M081B23 Metric mounting stud, 10-32 to M5 x 0.80, 0.275" long 1
081B05 Mounting stud, 10-32 to 10-32, 0.275" long, BeCu w/shoulder 2

Optional Versions


(M) Metric Mount

English SI
Acceleration Output (±3 %) 1.02 g rms 10.0 m/s² rms