hydraulic pump icp® pressure sensor, 10k psi, 0.5 mv/psi (long life integral diaphragm)

ICP® PRESSURE SENSOR

Model 108A02

  • CE
  • IP

Hydraulic pump ICP® pressure sensor, 10k psi, 0.5 mV/psi (long life integral diaphragm)

  • Measurement Range: 10 kpsi (69000 kPa)
  • Sensitivity: (±15%)0.5 mV/psi (0.073 mV/kPa)
  • Low Frequency Response: (-5%)0.01 Hz
  • Resonant Frequency: >=250 kHz (>=250 kHz)
  • Electrical Connector: 10-32 Coaxial Jack
  • Weight: 0.42 oz (12 gm)

Specification Notes


[1] Zero-based, least-squares, straight line method.
[2] Typical.
[3] For +10 volt output, minimum 24 VDC supply voltage required. Negative 10 volt output may be limited by output bias.
[2] Typical.
[4] See PCB Declaration of Conformance PS023 for details.

English: SI:
Performance
Measurement Range (for ±5V output) 10 kpsi 69000 kPa
Useful Overrange (for ± 10V output) 20000 psi 137900 kPa [3]
Sensitivity (±15 %) 0.5 mV/psi 0.073 mV/kPa
Maximum Pressure 50 kpsi 345000 kPa
Resolution 200 mpsi 1.4 kPa [2]
Resonant Frequency ≥250 kHz ≥250 kHz
Rise Time (Reflected) ≤2 µ sec ≤2 µ sec
Low Frequency Response (-5 %) 0.01 Hz 0.01 Hz
Non-Linearity ≤2 % FS ≤2 % FS [1]
Environmental
Acceleration Sensitivity 0.05 psi/g 0.035 kPa/(m/s²) [2]
Temperature Range (Operating) -100 to +275 °F -73 to +135 °C
Temperature Coefficient of Sensitivity ≤0.10 %/°F ≤0.18 %/°C
Maximum Vibration 2000 g pk 19600 m/s² pk
Maximum Shock 20000 g pk 196000 m/s² pk
Electrical
Output Polarity (Positive Pressure) Positive Positive
Discharge Time Constant (at room temp) ≥50 sec ≥50 sec
Excitation Voltage 20 to 30 VDC 20 to 30 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance ≤100 Ohm ≤100 Ohm
Output Bias Voltage 8 to 14 VDC 8 to 14 VDC
Physical
Sensing Geometry Compression Compression
Sensing Element Quartz Quartz
Housing Material C-300 C-300
Diaphragm C-300 C-300
Sealing Welded Hermetic Welded Hermetic
Electrical Connector 10-32 Coaxial Jack 10-32 Coaxial Jack
Weight 0.42 oz 12 gm

* All specifications are at room temperature unless otherwise specified.

Accessories


Supplied
PCS-1 Calibration of dynamic pressure sensors at 20% intervals to full scale, max 15 kpsi range. 0
065A06 Seal ring, 0.318" OD x 0.250" ID x 0.010" thick, 316L SS (for Series 108, 109, 118 and 119) 3

Optional Versions


Build Out Your Measurement Chain


410C01
Model: 410C01

ICP® sensor signal cond., 35mm DIN-rail ...

$902.00 USD

(Pricing valid only in the U.S.)

002C10
Model: 002C10

General purpose coaxial cable, white FEP...

$57.00 USD

(Pricing valid only in the U.S.)

002C20
Model: 002C20

General purpose coaxial cable, white FEP...

$67.00 USD

(Pricing valid only in the U.S.)