4-conductor, shielded, stainless steel armor-jacketed, polyurethane cable, 0.312 dia. (price per foot)

Cable

Model 043

Retrieving Price...

(Pricing valid only in the U.S.)

Units in Stock Lead Times
More on the way Call for Lead Time
  • IP

4-conductor, shielded, stainless steel armor-jacketed, polyurethane cable, 0.312" dia. (price per foot)

  • Cable Style: Multi Conductor - Shielded
  • Number of Conductors: 4
  • Cable Jacket Material: Polyurethane
  • Temperature Range: -58 to +250 °F (-50 to +121 °C)

Specification Notes


[1] Typical.

English: SI:
Performance
Number of Conductors 4 4
Cable Style Multi Conductor - Shielded Multi Conductor - Shielded
Cable Configuration Twisted Bundle Twisted Bundle
Environmental
Temperature Range -58 to +250 °F -50 to +121 °C
Electrical
Capacitance (conductor to conductor @ 70 °F (21 °C)) 36 pF/ft 118.11 pF/m
Physical
Cable Jacket Diameter (±.010 in) 0.25 in 6.35 mm [1]
Cable Jacket Material Polyurethane Polyurethane
Cable Jacket Color Black Black
Protective Covering Diameter 0.41 in 10.41 mm [1]
Protective Covering Stainless Steel Armor Stainless Steel Armor
Conductor Style Stranded - 19 strands 32 AWG Stranded - 19 strands 32 AWG
Conductor Material Tin Plated Copper Tin Plated Copper
Conductor Diameter (20 AWG) 0.040 in 1.016 mm [1]
Shield Type Over Bundle Braid: 90% Minimum Coverage Braid: 90% Minimum Coverage
Shield Material Over Bundle Tin Plated Copper Tin Plated Copper
Shield Wire Diameter Over Bundle (Each Strand 36 AWG) 0.19 in 4.70 mm [1]
Bend Radius (minimum) 4.10 in 104.14 mm
Weight 1.69 oz/ft 157.19 gm/m [1]

* All specifications are at room temperature unless otherwise specified.