Products

shock, icp® accel., 0.1 mv/g, 50 kg, 10-ft integral cable, 1/4-28 integral stud mechanically isolated

SHEAR ICP® Shock Accelerometer

Model 350D02

Retrieving Price...

(Pricing valid only in the U.S.)

Units in Stock Lead Times
4 Call for Lead Time
  • CE
  • IP

Shock, ICP® accel., 0.1 mV/g, 50 kg, 10-ft integral cable, 1/4-28 integral stud mechanically isolated

  • Sensitivity: (±30%)0.1 mV/g (0.01 mV/(m/s²))
  • Measurement Range: ±50000 g pk (±490000 m/s² pk)
  • Frequency Range: (±1dB)4 to 10000 Hz
  • Electrical Filter Corner Frequency: (-3dB)17 kHz
  • Mechanical Filter Resonant Frequency: 35 kHz
  • Weight: 0.16 oz (4.5 gm)

Additional configurations:

Specification Notes


[1] Typical.
[2] Typical corner frequency for coupled electrical and mechanical filters.
[3] Electrical filter is a second order filter.
[4] Amplitude at resonance is +9 dB.
[1] Typical.
[5] Test conducted on shaker at 100Hz.
[1] Typical.
[6] See PCB Declaration of Conformance PS135 for details.

English: SI:
Performance
Sensitivity (±30 %) 0.1 mV/g 0.01 mV/(m/s²)
Measurement Range ±50000 g pk ±490000 m/s² pk
Frequency Range (±1 dB) 4 to 10000 Hz 4 to 10000 Hz
Frequency Range (-3 dB) 2 to 25000 Hz 2 to 25000 Hz [2]
Electrical Filter Corner Frequency (-3 dB) 17 kHz 17 kHz [1] [3]
Mechanical Filter Resonant Frequency 35 kHz 35 kHz [1] [4]
Resonant Frequency ≥100 kHz ≥100 kHz
Broadband Resolution (1) 0.5 g rms 4.9 m/s² rms [1]
Non-Linearity (per 10,000 g (98,100 m/s²)) 2.5 % 2.5 %
Transverse Sensitivity ≤7 % ≤7 %
Environmental
Overload Limit (Shock) ±150000 g pk ±1471500 m/s² pk
Temperature Range (Operating) -10 to +150 °F -23 to +66 °C
Temperature Range (Storage) -40 to +200 °F -40 to +93 °C
Temperature Response See Graph %/°F See Graph %/°F [1] [5]
Electrical
Excitation Voltage 20 to 30 VDC 20 to 30 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance ≤200 Ohm ≤200 Ohm
Output Bias Voltage 8 to 14 VDC 8 to 14 VDC
Discharge Time Constant 0.10 sec 0.10 sec [1]
Settling Time (within 10% of bias) <1 sec <1 sec
Electrical Isolation (Case) >1000000 Ohm >1000000 Ohm
Physical
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Housing Material Titanium Titanium
Sealing Hermetic Hermetic
Size - Hex 0.375 in 9.5 mm
Size - Height 0.87 in 22.1 mm
Weight (without cable) 0.16 oz 4.5 gm [1]
Electrical Connector Integral Cable Integral Cable
Cable Length 10 ft 3.05 m
Cable Type 031 Twisted Pair 031 Twisted Pair
Mounting Thread 1/4-28 Male 1/4-28 Male

* All specifications are at room temperature unless otherwise specified.

TempChart

Accessories


Supplied
ACS-14 High G accel. verification using Hopkinson bar to max g range, (NIST traceable). 1
ACS-22 **OBSOLETE see ACS-22/ACS-14** Amplitude response cal for shock accel, 100 Hz to upper 1 dB freq (max 15 kHz) 1

Optional Versions


(M) Metric Mount

English SI
Mounting Thread M6 x 0.75 Male

Build Out Your Measurement Chain