Products

quartz, free-field, icp® blast pressure pencil probe, 500 psi, 10 mv/psi, 4-pin connector, with two outputs for t.o.a

ICP® Pressure Sensor

Model 137B27

Retrieving Price...

(Pricing valid only in the U.S.)

Units in Stock Lead Times
More on the way Lead Time for 1-5 is 6 Wks.
Lead Time for 6-10 is 8 Wks.
  • CE
  • IP

Quartz, free-field, ICP® blast pressure pencil probe, 500 psi, 10 mV/psi, 4-pin connector, with two outputs for T.O.A

  • Measurement Range: 500 psi (3447 kPa)
  • Sensitivity: (±15%)10 mV/psi (1.45 mV/kPa)
  • Resonant Frequency: >=400 kHz
  • Electrical Connector: 4-Pin
  • Weight: 16.1 oz (456 gm)

Specification Notes


[1] Zero-based, least-squares, straight line method.
[2] Typical.
[3] For +10 volt output, minimum 26 VDC supply voltage required. Negative 10 volt output may be limited by output bias.
[4] Two identically spec'd elements spaced 10cm apart - see drawing #65310 for details. Individual calibration certs supplied for each channel.
[2] Typical.
[5] See PCB Declaration of Conformance PS023 for details.

English: SI:
Performance
Measurement Range (for ±5V output) 500 psi 3447 kPa
Useful Overrange (for ± 10V output) 1000 psi 6895 kPa [3]
Sensitivity (±15 %) 10 mV/psi 1.45 mV/kPa [4]
Maximum Pressure 5 kpsi 34474 kPa
Resolution 1 mpsi 0.007 kPa [2]
Resonant Frequency ≥400 kHz ≥400 kHz
Rise Time (Incident) ≤6.5 µ sec ≤6.5 µ sec
Non-Linearity ≤1.0 % FS ≤1.0 % FS [1]
Environmental
Temperature Range (Operating) -100 to +275 °F -73 to +135 °C
Temperature Coefficient of Sensitivity ≤0.05 %/°F ≤0.090 %/°C
Electrical
Discharge Time Constant (at room temp) ≥0.2 sec ≥0.2 sec
Excitation Voltage 20 to 30 VDC 20 to 30 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance ≤100 Ohm ≤100 Ohm
Output Bias Voltage 8 to 14 VDC 8 to 14 VDC
Physical
Sensing Geometry Compression Compression
Sensing Element Quartz Quartz
Housing Material Aluminum Aluminum
Diaphragm Invar Invar
Sealing Epoxy Epoxy
Electrical Connector 4-Pin 4-Pin
Weight 16.1 oz 456 gm [2]

* All specifications are at room temperature unless otherwise specified.

Accessories


Supplied
PCS-6AA 0