dual output, vibration & resistance temperature detector (rtd), low profile, industrial, ceramic shear icp® accel., 100 mv/g, 0.5 to 8000 hz, 6 conductor 10 ft integral cable (522), rtd configurable to 2, 3, 4, wire configuration

Industrial ICP® Accelerometer with RTD

Model RTD602D11

  • CE
  • IP

Dual output, vibration & Resistance Temperature Detector (RTD), low profile, industrial, ceramic shear ICP® accel., 100 mV/g, 0.5 to 8000 Hz, 6 conductor 10 ft integral cable (522), RTD configurable to 2, 3, 4, wire configuration

  • Sensitivity: (±10%)100 mV/g (10.2 mV/(m/s²))
  • Frequency Range: (±3dB)30 to 480000 cpm (0.5 to 8000 Hz)
  • Sensing Element: Ceramic
  • Measurement Range: ±50 g (±490 m/s²)
  • Weight: 2.68 oz (76 gm)

Additional configurations:

Specification Notes


[1] Conversion Factor 1g = 9.81 m/s².
[2] Zero-based, least-squares, straight line method.
[3] The high frequency tolerance is accurate within ±10% of the specified frequency.
[4] Typical.
[5] 1/4-28 has no equivalent in S.I. units.
[4] Typical.
[6] Cable length for A0325TO-1 is 10 feet [3.0 meters]. Cable length for A0325TO-2 is 30 feet [9.1 meters].
[7] 6 Conductor Shielded Cable
[8] See PCB Declaration of Conformance PS023 for details.

English: SI:
Performance
Sensitivity (±10 %) 100 mV/g 10.2 mV/(m/s²) [1]
Measurement Range ±50 g ±490 m/s²
Frequency Range (±3 dB) 30 to 480000 cpm 0.5 to 8000 Hz [3]
Resonant Frequency 1500 kcpm 25 kHz [4]
Broadband Resolution (1) 350 µg 3434 µm/sec2 [4]
Non-Linearity ±1 % ±1 % [2]
Transverse Sensitivity ≤7 % ≤7 %
Environmental
Overload Limit (Shock) 5000 g pk 49050 m/s² pk
Temperature Range -65 to +250 °F -54 to +121 °C
Temperature Response See Graph %/°F See Graph %/°F
Enclosure Rating IP68 IP68
Electrical
Settling Time (within 1% of bias) ≤2.0 sec ≤2.0 sec
Discharge Time Constant ≥0.3 sec ≥0.3 sec
Excitation Voltage 18 to 28 VDC 18 to 28 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance <150 Ohm <150 Ohm
Output Bias Voltage 8 to 12 VDC 8 to 12 VDC
Spectral Noise (10 Hz) 8.0 µg/√Hz 78.5 (µm/sec2)/√Hz [4]
Spectral Noise (100 Hz) 5 µg/√Hz 49.1 (µm/sec2)/√Hz [4]
Spectral Noise (1 kHz) 4 µg/√Hz 39.2 (µm/sec2)/√Hz [4]
Electrical Isolation (Case) >100000000 Ohm >100000000 Ohm
Physical
Size - Length 3.70 in 94 mm
Size - Width 0.74 in 18.8 mm
Size - Height 0.845 in 21.5 mm
Weight (without cable) 2.68 oz 76 gm [4]
Mounting Thread 1/4-28 Male No Metric Equivalent [5]
Mounting Torque 2 to 5 ft-lb 2.7 to 6.8 Nm
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Sensing Element (Temperature) PT100 PT100
Housing Material Stainless Steel Stainless Steel
Sealing Welded Hermetic Welded Hermetic
Electrical Connector Molded Integral Cable Molded Integral Cable
Electrical Connection Position Side Side
Cable Length See Note See Note [6]
Cable Type Polyurethane Polyurethane [7]

* All specifications are at room temperature unless otherwise specified.

TempChart

Accessories


Supplied
081B97 CAPTIVE MOUNTING BOLT 316SS- 7/16 HEX, 1/4-28 UNF, 1 INCH LENGTH 1
ICS-2 Calibration of industrial accel., single-point, 100 Hz reference sensitivity 1

Optional Versions


(M) Metric Mount
Accessories:
Supplied M081B97 Captive Mounting Bolt 1