platinum stock products; low profile, industrial, ceramic shear icp® accel., 100 mv/g, 0.5 to 8000 hz, side exit, 2-pin connector, single point iso 17025 accredited calibration
platinum

Platinum Low-cost Industrial ICP® Accelerometer

Model M602D01

Retrieving Price...

(Pricing valid only in the U.S.)

Units in Stock Lead Times
More on the way Lead Time for 1-10 is 14 Dys.
Lead Time for 11-25 is 3 Wks.
  • CE
  • IP

Platinum Stock Products; Low profile, industrial, ceramic shear ICP® accel., 100 mV/g, 0.5 to 8000 Hz, side exit, 2-pin connector, single point ISO 17025 accredited calibration

  • Sensitivity: (±10%)100 mV/g (10.2 mV/(m/s²))
  • Frequency Range: (±3dB)30 to 480000 cpm (0.5 to 8000 Hz)
  • Sensing Element: Ceramic
  • Measurement Range: ±50 g (±490 m/s²)
  • Weight: 2.61 oz (74.0 gm)

Specification Notes


[1] Conversion Factor 1g = 9.81 m/s².
[2] Zero-based, least-squares, straight line method.
[3] The high frequency tolerance is accurate within ±10% of the specified frequency.
[4] Typical.
[5] 1/4-28 has no equivalent in S.I. units.
[6] See PCB Declaration of Conformance PS023 or PS060 for details.

English: SI:
Performance
Sensitivity (±10 %) 100 mV/g 10.2 mV/(m/s²) [1]
Measurement Range ±50 g ±490 m/s²
Frequency Range (±3 dB) 30 to 480000 cpm 0.5 to 8000 Hz [3]
Resonant Frequency 1500 kcpm 25 kHz [4]
Broadband Resolution 350 µg 3434 µm/sec2 [4]
Non-Linearity ±1 % ±1 % [2]
Transverse Sensitivity ≤7 % ≤7 %
Environmental
Overload Limit (Shock) 5000 g pk 49050 m/s² pk
Temperature Range -65 to +250 °F -54 to +121 °C
Temperature Response See Graph %/°F See Graph %/°F [4]
Enclosure Rating IP68 IP68
Electrical
Settling Time (within 1% of bias) ≤2.0 sec ≤2.0 sec
Discharge Time Constant ≥0.3 sec ≥0.3 sec
Excitation Voltage 18 to 28 VDC 18 to 28 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance <150 Ohm <150 Ohm
Output Bias Voltage 8 to 12 VDC 8 to 12 VDC
Spectral Noise (10 Hz) 8.0 µg/√Hz 78.5 (µm/sec2)/√Hz [4]
Spectral Noise (100 Hz) 5 µg/√Hz 49.1 (µm/sec2)/√Hz [4]
Spectral Noise (1 kHz) 4 µg/√Hz 39.2 (µm/sec2)/√Hz [4]
Electrical Isolation (Case) >100000000 Ohm >100000000 Ohm
Physical
Size - Length 1.65 in 41.9 mm
Size - Width 0.74 in 18.8 mm
Size - Height 0.845 in 21.5 mm
Weight 2.61 oz 74.0 gm
Mounting Thread 1/4-28 Male No Metric Equivalent [5]
Mounting Torque 2 to 5 ft-lb 2.7 to 6.8 Nm
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Housing Material Stainless Steel Stainless Steel
Sealing Welded Hermetic Welded Hermetic
Electrical Connector 2-Pin MIL-C-5015 2-Pin MIL-C-5015
Electrical Connection Position Side Side

* All specifications are at room temperature unless otherwise specified.

TempChart

Accessories


Supplied
081B97 CAPTIVE MOUNTING BOLT 316SS- 7/16 HEX, 1/4-28 UNF, 1 INCH LENGTH 1

Optional Versions


(EX) Hazardous Area Approval- contact factory for specific approvals

English SI
Hazardous Area Approval EEx nL IIC T4, -40 ° C ≤ Ta ≤ 121 ° C, II 1 G
Hazardous Area Approval Cl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I
Hazardous Area Approval Ex ia IIC T4, AExia IIC, T4
Hazardous Area Approval Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4
Hazardous Area Approval Ex nL IIC T4, -40°C≤Ta≤121°C, II 3 G
Hazardous Area Approval EEx nL IIC T4, -40 ° C ≤ Ta ≤ 121 ° C, II 3 G
Hazardous Area Approval EEx ia IIC T4, -40 ° C ≤ Ta ≤ 121 ° C, II 1 G
Hazardous Area Approval Cl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I
Hazardous Area Approval Ex ia IIC T4, AExia IIC, T4
Hazardous Area Approval Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4
Hazardous Area Approval EEx nL IIC T4, -40 ° C ≤ Ta ≤ 121 ° C, II 1 G
Hazardous Area Approval Cl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I
Hazardous Area Approval Ex ia IIC T4, AExia IIC, T4
Hazardous Area Approval Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4
Hazardous Area Approval Ex nL IIC T4, -40°C≤Ta≤121°C, II 3 G
Hazardous Area Approval EEx nL IIC T4, -40 ° C ≤ Ta ≤ 121 ° C, II 3 G
Hazardous Area Approval EEx ia IIC T4, -40 ° C ≤ Ta ≤ 121 ° C, II 1 G
Hazardous Area Approval Cl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I
Hazardous Area Approval Ex ia IIC T4, AExia IIC, T4
Hazardous Area Approval Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4
(M) Metric Mount
Accessories:
Supplied M081B97 Captive Mounting Bolt 1

(TO) Temperature Output

English SI
Temperature Output Range +36 to +250 °F +2 to +121 °C
Temperature Scale Factor 5.56 mV/°F + 32 +10 mV/°C
Electrical Connector 3-Pin
Electrical Connections Acceleration Output
Electrical Connections Temperature Output
Electrical Connections Ground