 | | Model 200B01 | | Impact ICP® quartz force sensor, 10 lb comp., 500 mV/lb Measurement Range: (Compression) 10 lb (0.04448 kN)Sensitivity: (±15%) 500 mV/lb (112410 mV/kN)Low Frequency Response: (-5%) 0.01 Hz Upper Frequency Limit: 75000 Hz Temperature Range: -65 to +250 °F (-54 to +121 °C)Mounting Thread: 10-32 Female |
|
 | | Model 200B02 | | Impact ICP® quartz force sensor, 100 lb comp., 50 mV/lb Measurement Range: (Compression) 100 lb (0.4448 kN)Sensitivity: (±15%) 50 mV/lb (11241 mV/kN)Low Frequency Response: (-5%) 0.001 Hz Upper Frequency Limit: 75000 Hz Temperature Range: -65 to +250 °F (-54 to +121 °C)Mounting Thread: 10-32 Female |
|
 | | Model 200B03 | | Impact ICP® quartz force sensor, 500 lb comp., 10 mV/lb Measurement Range: (Compression) 500 lb (2.224 kN)Sensitivity: (±15%) 10 mV/lb (2248.2 mV/kN)Low Frequency Response: (-5%) 0.0003 Hz Upper Frequency Limit: 75000 Hz Temperature Range: -65 to +250 °F (-54 to +121 °C)Mounting Thread: 10-32 Female |
|
 | | Model 200B04 | | Impact ICP® quartz force sensor, 1k lb comp., 5 mV/lb Measurement Range: (Compression) 1000 lb (4.448 kN)Sensitivity: (±15%) 5 mV/lb (1124 mV/kN)Low Frequency Response: (-5%) 0.0003 Hz Upper Frequency Limit: 75000 Hz Temperature Range: -65 to +250 °F (-54 to +121 °C)Mounting Thread: 10-32 Female |
|
 | | Model 200B05 | | Impact ICP® quartz force sensor, 5k lb comp., 1 mV/lb Measurement Range: (Compression) 5000 lb (22.24 kN)Sensitivity: (±15%) 1 mV/lb (224.82 mV/kN)Low Frequency Response: (-5%) 0.0003 Hz Upper Frequency Limit: 75000 Hz Temperature Range: -65 to +250 °F (-54 to +121 °C)Mounting Thread: 10-32 Female |
|
 | | Model 200C20 | | Impact ICP® quartz force sensor, 20k lb comp., 0.25 mV/lb Measurement Range: (Compression) 20000 lb (88.96 kN)Sensitivity: (±15%) 0.25 mV/lb (56.2 mV/kN)Low Frequency Response: (-5%) 0.0003 Hz Upper Frequency Limit: 40000 Hz Temperature Range: -65 to +250 °F (-54 to +121 °C)Mounting Thread: 1/4-28 Female (Not Applicable) |
|
 | | Model 200C50 | | Impact ICP® quartz force sensor, 50k lb comp., 0.10 mV/lb Measurement Range: (Compression) 50000 lb (222.4 kN)Sensitivity: (±15%) 0.10 mV/lb (22.48 mV/kN)Low Frequency Response: (-5%) 0.0003 Hz Upper Frequency Limit: 30000 Hz Temperature Range: -65 to +250 °F (-54 to +121 °C)Mounting Thread: 1/4-28 Female (Not Applicable) |
|
 | | Model 201B01 | | ICP® quartz force ring, 10 lb comp., 500 mV/lb Measurement Range: (Compression) 10 lb (0.04448 kN)Sensitivity: (±15%) 500 mV/lb (112405 mV/kN)Low Frequency Response: (-5%) 0.01 Hz Upper Frequency Limit: 90000 Hz Temperature Range: -65 to +250 °F (-54 to +121 °C) |
|
 | | Model 201B02 | | ICP® quartz force ring, 100 lb comp., 50 mV/lb Measurement Range: (Compression) 100 lb (0.4448 kN)Sensitivity: (±15%) 50 mV/lb (11240 mV/kN)Low Frequency Response: (-5%) 0.006 Hz Upper Frequency Limit: 90000 Hz Temperature Range: -65 to +250 °F (-54 to +121 °C) |
|
 | | Model 201B03 | | ICP® quartz force ring, 500 lb comp., 10 mV/lb Measurement Range: (Compression) 500 lb (2.224 kN)Sensitivity: (±15%) 10 mV/lb (2248 mV/kN)Low Frequency Response: (-5%) 0.002 Hz Upper Frequency Limit: 90000 Hz Temperature Range: -65 to +250 °F (-54 to +121 °C) |
|